Whole House Heat Loss Formula:
From: | To: |
Whole house heat loss refers to the total amount of heat energy that escapes from a building through various pathways including walls, windows, roofs, floors, and ventilation. Understanding heat loss is crucial for proper heating system sizing and energy efficiency improvements in UK homes.
The calculator uses the whole house heat loss formula:
Where:
Explanation: This formula calculates the rate at which heat is lost from the entire building envelope, considering the building volume, temperature gradient, and overall thermal performance.
Details: Accurate heat loss calculation is essential for sizing heating systems correctly, improving energy efficiency, reducing fuel costs, and ensuring comfortable indoor temperatures throughout UK winters.
Tips: Enter building volume in cubic meters, temperature difference in °C, and the appropriate heat loss factor. Typical factors range from 0.8 W/m³°C for well-insulated new builds to 2.5 W/m³°C for poorly insulated older properties.
Q1: What is a typical heat loss factor for UK homes?
A: For modern well-insulated homes: 0.8-1.2 W/m³°C; for average older homes: 1.5-2.0 W/m³°C; for poorly insulated properties: 2.0-2.5 W/m³°C.
Q2: How do I calculate building volume?
A: Multiply floor area by ceiling height. For irregular shapes, calculate volume for each section and sum them.
Q3: What temperature difference should I use?
A: Use the difference between desired indoor temperature (typically 20-21°C) and design external temperature (typically -1 to -3°C for UK).
Q4: Why is this important for boiler sizing?
A: Oversized boilers cycle frequently reducing efficiency, while undersized boilers cannot maintain comfort during cold weather.
Q5: How can I reduce heat loss in my home?
A: Improve insulation, upgrade windows, seal drafts, install mechanical ventilation with heat recovery, and consider renewable heating systems.